Connect the MBMs to service providers

To connect DTM, CTM, CTM8, BRIM S/T, or 4x16 MBMs

1

On the front of the MBM, locate the RJ-48C jack (DTM), RJ-45 jack (BRIM), or the RJ-11
jacks (CTM and 4x16).

2

Wire one end of the cable to the demarcation blocks of the building.

Figure 76

shows the wiring pin-outs for a DTM to connect to a service provider.

Figure 76 DTM RJ-48C wiring array

Figure 77

shows the wiring pin-out for a CTM4, a CTM8, or the CTM jacks on a 4x16 MBM

to connect to the service provider.

All the MBMs have an auxiliary jack (the CTM8 has two). Do not attempt to plug digital
equipment into this jack.

Figure 77 CTM RJ-11 wiring array

Warning: If you are using a service provider channel service unit (CSU), you must
disable the BCM system internal CSU.

1 2 3 4 5 6 7 8

DTM connector

To network

To plug

Receive from

network

1- Rring

2 - Rtip

3 - Rshield

Transmit to network

4-Tring

5-Ttip

6-Tshield

RJ-48C jack

6 5 4 3 2 1

CTM
connector

RJ-11 jacks

Auxiliary jack

Pin #/connection

3- Ring

4 - Tip

The CTM8 has ten RJ-11 jacks, including two
auxiliary jacks.

The 4x16 and CTM4 MBMs have four RJ-11 jacks.