Loop current
20 mA minimum
20 mA minimum
20 mA minimum
20 mA minimum
20 mA minimum
Battery feed voltage
-48 V dc
±
10%
-48 V dc
±
10%
-29 V dc
±
10%
-48 V dc
±
10%
-48 V dc
±
10%
FIC code
OL13ABC
N/A
N/A
N/A
N/A
Ringer equivalency
number
3
1
2
2
2
ATA2 to BCM loop
resistance (cable only)
135 ohms
(800 m of
0.5-mm wire or
2600 ft of 24
AWG wire)
N/A
N/A
N/A
N/A
Analog loop resistance
on terminal side for
voice applications
(cable only)
1300 ohms
(7200 m of
0.5-mm wire or
26000 ft of 24
AWG wire)
250 ohms (1538
m of 0.5-mm
wire or 5000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
Analog loop resistance
on terminal side for
data applications
(cable only)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
250 ohms (1538
m of 0.5-mm
wire or 5000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
200 ohms (1231
m of 0.5-mm
wire or 4000 ft of
24 AWG wire)
Input impedance at tip
and ring
600 ohms
600 ohms
600 ohms
600 ohms
600 ohms
Return loss
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
> 20 dB for 200
to 3400 Hz
(when
terminated with
600 ohms)
Insertion loss on an
internal call
ATA2 to BCM
loss 3.0 dB
±
0.5
dB
ATA2 to BCM
loss 3.0 dB
±
0.5
dB
ATA2 to BCM
loss 3.0 dB
±
0.5
dB
ATA2 to BCM
loss 3.0 dB
±
0.5
dB
ATA2 to BCM
loss 3.0 dB
±
0.5
dB
Insertion loss on an
external call
ATA2 to BCM
loss 2.2 dB +/-
1.0 dB; BCM to
ATA2 loss 0.5 dB
±
1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
±
1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
±
1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
±
1.0 dB
ASM to BCM
loss 3.0 dB +/-
1.0 dB; BCM to
ASM loss 0.5 dB
±
1.0 dB
MWI type (see Note)
Stutter tone
Stutter tone
Stutter tone/
/ Voltage MWI
(CO: 120 V)
Stutter tone/
Reverse polarity/
Voltage MWI
(CO: 120 V)
Stutter Tone/
Reverse polarity/
Voltage MWI
(PBX: 90 V)
Disconnect
supervision types
N/A
N/A
OSI EIA/TIA 464
section
4.5.10.2.4/
4.5.10.2.5.1
OSI EIA/TIA 464
section
4.5.10.2.4/
4.5.10.2.5.1
N/A
Note: The MWI type depends on the country profile, and the MWI voltage shown is a maximum value.
Table 10 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 2 of 2)
Specification
ATA2
ASM8
ASM8+
GASM8
GASI