Chapter 23 Replacing or upgrading a power supply

N0060612

N0060612

To remove the PSU status connector jumper

1

Shut down the system (see

“Performing a system shutdown” on page 239

).

2

Disconnect the BCM400 system from the AC power outlet.

3

Remove the main unit top cover. Refer to

“Removing the main unit top cover” on page 252

.

4

Locate the PSU status connector on the I/O card (see

Figure 149

).

5

Remove the RPS output signaling connector jumper. Use needle-nose pliers to pull the jumper
out and away from the connector. Place the jumper in a safe location.

6

Connect the PA cable to the PSU status connector (see

Figure 149 on page 296

).

Figure 149 Remove the PSU status connector jumper

Installing a redundant power supply cage (BCM400 only)

This procedure describes how to install a redundant power supply cage in the BCM400 main unit.
After you install the redundant power supply cage in the main unit, install the two power supply
modules (see

“Installing a power supply module” on page 303

).

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.

Note: When you upgrade to a redundant power supply, you must also install a redundant
fan. Refer to

“Installing a BCM400 cooling fan” on page 334

.

I/O Card

PSU Status
connector

Jumper