To remove the psu status connector jumper – Nortel Networks BCM200/400 User Manual
Page 296
296
Chapter 23 Replacing or upgrading a power supply
N0060612
N0060612
To remove the PSU status connector jumper
1
Shut down the system (see
“Performing a system shutdown” on page 239
).
2
Disconnect the BCM400 system from the AC power outlet.
3
Remove the main unit top cover. Refer to
“Removing the main unit top cover” on page 252
.
4
Locate the PSU status connector on the I/O card (see
).
5
Remove the RPS output signaling connector jumper. Use needle-nose pliers to pull the jumper
out and away from the connector. Place the jumper in a safe location.
6
Connect the PA cable to the PSU status connector (see
).
Figure 149 Remove the PSU status connector jumper
Installing a redundant power supply cage (BCM400 only)
This procedure describes how to install a redundant power supply cage in the BCM400 main unit.
After you install the redundant power supply cage in the main unit, install the two power supply
modules (see
“Installing a power supply module” on page 303
).
Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.
Note: When you upgrade to a redundant power supply, you must also install a redundant
fan. Refer to
“Installing a BCM400 cooling fan” on page 334
.
I/O Card
PSU Status
connector
Jumper