Chapter 3 Viewing the BCM system LEDs

N0060612

N0060612

Figure 47 MBM LEDs

Table 20

describes the possible MBM LED states.

The following MBMs have additional LEDs:

“DTM LEDs” on page 82

“BRIM LEDs” on page 84

DTM LEDs

The DTM has additional LEDs that are not on most other MBMs.

Figure 48

shows the location of

the DTM LEDs.

Table 20 MBM LED descriptions

Power Status

Description

Off

Off

The MBM does not have power, or there is a failure of the MBM power converter.

On

Off

BCM to expansion unit failure or system initialization.

On

Blinking

Hardware is working, but there is an operational problem such as:

no link to main unit is detected

frame alignment is lost on messages from the main unit

bandwidth not allocated

MBM is in maintenance state

MBM is in download state (GASM, GATM4/GATM8)

Blinking

Blinking

The MBM has power, but there is a hardware problem such as:

partial failure of power converter

thermal overload

fan failure

On

On

The MBM is ready to operate.