BCM200/400 4.0 Installation and Maintenance Guide

Figure 48 DTM LEDs

Table 21

describes the functions of the DTM LEDs.

Table 21 DTM LED functions

LED Status

Descriptions

Power

Refer to

“Media bay module LEDs”

for details.

Status

Refer to

“Media bay module LEDs”

for details.

In service

Flashing

The T1, ETSI, or PRI trunks are out of service because a loopback test is
running or the DTM is initializing.

Loopback test

On

A continuity loopback test is running.

Receive alarm

On

A problem with the received digital transmission. This half-duplex link does
not work.

Receive error

On

A small error as a result of degraded digital transmission. Possible causes are
an ohmic connection, water ingress, or too long a loop.

Transmit alarm

On

The DTM cannot transmit. The DTM sends an alarm indication signal (AIS) to
the terminating switch. This half-duplex link does not work.

Transmit error

On

The DTM is sending a remote alarm indication (RAI) carrier failure alarm
(CFA) to the terminating switch. If the transmit alarm is not on, this error
indicates a far-end or cable problem.

All LEDs

Flashing

The DTM is initializing.

Tip: You can install a maximum of three DTM modules in the BCM main unit, depending
on the available buses.