beautypg.com

Te in, Table 45 – Nortel Networks BCM200/400 User Manual

Page 138

background image

138

Chapter 8 Installing a media bay module (MBM)

N0060612

N0060612

DSM16+ and DSM 32+ double density switch settings (upgraded system)

The following table shows the switch settings for DSM-plus modules deployed as double density
on a system that has been upgraded from BCM 2.5 to BCM 3.0 or later software.

Table 45 DSM16/DSM16+ and DSM32/DSM32+ single-density switch settings (upgraded system)

Select

DS30

bus

Enter these switch

settings

**To assign these

DNs to

DSM16 or

DSM 16+

To assign these DNs to

DSM 32 or DSM 32+

1

2

3

4

5

6

2

on

on

on

on on on

221-236

221-252 (DS30 2 and 3)

3

on

on

on

on on off

237-252

237-268 (DS30 3 and 4)

4

on

on

on

on off on

253-268

253-284) (DS30 4 and 5)

5

on

on

on

on off off

269-284

269-300 (DS30 5 and 6)

6

on

on

on

off on on

285-300

285-316 (DS30 6 and 7)

***7

on

on

on

off on off

301-316

N/A

**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.

***If your system is configured with a 3/5 DS30 split, you cannot use DS30 7 for the DSM 16 module. You cannot
configure the DSM 32 module for DS30 6 because the second set of DNs cannot be accessed.

Note: DSM modules deployed with BCM 2.5 systems are all single density and cannot be
set to double density. The DSM 16+ and DSM32+ modules can be set to either density.

Table 46 DSM 16+ and DSM32+ double density switch settings (upgraded system)

Select

DS30

bus

Enter these switch settings

*To assign these DNs

to

DSM 16+:

(A= DSM1, B=DSM2)

To assign these DNs to

DSM 32+

(connectors: A=top,

B = bottom)

1

2

3

4

5

6

2

off

on

on

on

on

on A

221-236

A

377-392

off

on

off

on

on

on B

377-392

B

221-236

3

off

on

on

on

on

off A

237-252

A

393-408

off

on

off

on

on

off B

393-408

B

237-252

4

off

on

on

on

off

on A

253-268

A

409-424

off

on

off

on

off

on B

409-424

B

253-268

5

off

on

on

on

off

off A

269-284

A

425-440

off

on

off

on

off

off B

425-440

B

269-284

6

off

on

on

off

on

on A

285-300

A

441-456

off

on

off

off

on

on B

441-456

B

285-300

**7

off

on

on

off

on

off A

301-316

A

457-472

off

on

off

off

on

off B

457-472

B

301-316

* The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a