beautypg.com

Removing a bcm200 power supply, To remove the bcm200 power supply, Figure – Nortel Networks BCM200/400 User Manual

Page 284

background image

284

Chapter 23 Replacing or upgrading a power supply

N0060612

N0060612

Figure 134 Standard power supply replacement overview

Removing a BCM200 power supply

If the standard power supply fails, the system is down. Use this procedure to remove the standard
power supply from a BCM200 main unit.

To remove the BCM200 power supply

1

Set up the BCM200 for maintenance (see

“Performing a system shutdown” on page 239

).

2

Disconnect all cables from the front of the base function tray. Disconnect the main unit and the
expansion unit (if applicable) from the AC power connection.

3

Remove the top cover from the main unit (see

“Removing the main unit top cover” on page

252

).

4

Attach one end of the grounding strap to your wrist and the other end to a grounded metal
surface.

5

Locate and disconnect the power supply cables from the I/O card, media bay backplane, and
hard disk.

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.

Warning: Power supply cable management is critical. Loose or incorrectly positioned
cables can result in cable damage.

System down

Set up unit for
maintenance

Remove failed
power supply

Restore unit to
operation

Check Power LED

Reconnect power
supply cables

Check
connections

Install new power
supply

Disconnect
power supply
cables. Note
cable routing