Page 183: Required cables

background image

CAMERA ARRAY

SET UP A CAMERA ARRAY

NOTE:

Master/Slave operation, including stereo/3D and camera arrays, requires a GIG-E port, which is available on the

DSMC2 Jetpack-SDI Expander, DSMC2 REDVOLT Expander, and DSMC2 Production Module. For more information,
go to

"GIG-E (Ethernet)" on page 237

.

NOTE:

For genlock to function correctly, the cameras must be on the same firmware version, and must be using the

same project time base and recording frame rate.

NOTE:

To operate a camera array setup from a Windows

®

computer or workstation, you need one of several

applications provided by RED

®

or third-party developers.

You can sync more than two (2) cameras for applications and productions that require a camera array. To set up a
camera array, you need a 1000Base-T gigabit Ethernet router.

For more information on camera control, see the

R.C.P.™ SDK

, available at

www.red.com/developers

.

To set up a camera array, follow the instructions below:

 1. On each camera, go to

Menu

>

Settings

>

Setup

>

Communication

and set the following:

 A. On the

Camera

tab, set

Target

to

All

.

 B. On the

Camera

tab, enter a matching name in the

Group ID

field. All cameras must have the same Group ID

name.

 C. On the

Ethernet

tab, select the

DHCP

,

Camera to Camera

, and

External Control

check boxes.

 2. Follow the instructions in

"Sensor Sync" on page 176

to connect each camera to the genlock device.

The

GEN

and

SYNC

indicators in the Lower Status Row illuminate green.

 3. Follow the instructions in

"Set Up Master/Slave Operation" on page 178

to set Master and Slave camera settings.

Instead of using the Master/Slave Gig-E Cable, connect each camera to the router using a 9-Pin 0B GIG-E-To-
CAT5E Ethernet Cable.

 A. Connect the LCD/EVF connector to the

GIG-E

port on the expander or module.

 B. Connect the Ethernet connector to the router.

 4. On each camera, follow the instructions in

"Set Reel Number, Camera ID, and Camera Position" on page 180

to

prepare media and camera settings.

REQUIRED CABLES

Use one (1) per camera:

790-0154, 790-0643

: 3BNC-to-00 Sync Cable

DSMC2 REDVOLT Expander, DSMC2 Jetpack-SDI Expander or DSMC2 Production Module

: 75 ohm BNC

cable (such as the RED HD-SDI Cable, P/N 790-0341)

Use one (1) of the following per setup:

790-0159

: RED GIG-E Straight-to-CAT5E Ethernet Cable (9')

790-0557, 790-0655

: RED GIG-E Right-to-CAT5E Ethernet Cable (9')

C O PYR I G HT © 2 0 1 9 R ED.C O M , LLC

9 5 5 - 0 1 6 8 _V 7 .1 , R EV - M    

|

   1 8 3