5.5 Selecting Peripheral Devices
339
3)
Select 1CN connector for
reference input.
Connector only
1CN connector
DP9420010
Use circuit
breaker for 5 A
power supply
capacity.
Use circuit
breaker for 9 A
power supply
capacity.
Use circuit
breaker for 16 A
power supply
capacity.
Use circuit
breaker for 5 A
power supply
capacity.
Use circuit
breaker for 8 A
power supply
capacity.
Use circuit
breaker for 15 A
power supply
capacity.
Noise filter
Noise filter
Noise filter
Noise filter
from (c)
Servopack power
supply 200 V/100 V?
200 V
100 V
Servopack capacity?
Servopack capacity?
30 to 200W
400W
750W
30 to 100W
200W
300W
Noise filter
LF−205A
LF−220
LF−205A
LF−210
LF−220
4) Select circuit breaker (MCCB)
and noise filter.
Noise filter
LF−210
(0.04 to 0.27HP)
(0.53HP)
(1.01HP)
(0.04 to 0.13HP)
(0.27HP)
(0.40HP)
5)
Select magnetic contactor and
surge suppressor.
Magnetic
contactor
HI−15E5
D
Use one 30 A magnetic contactor for a single
Σ Series, regardless of capacity.
For multiple servo systems, select the
magnetic contactor according to the total
capacity.
to (d)
5