Yaskawa DR2 Sigma Servo User Manual
Page 143
APPLICATIONS OF Σ-SERIES PRODUCTS
3.7.1 Using Servo Alarm Output and Alarm Code Output cont.
130
4) Relationship between Alarm Display and Alarm Code Output
Alarm Display and Alarm Code Output:
Alarm
Alarm Code Output
Servo
Alarm
Alarm Type
Alarm Description
Alarm
Display
ALO1 ALO2 ALO3
Alarm
(ALM+)
Output
Alarm Type
Alarm Description
¢
¢
¢
¢
User
constant
error
An absolute encoder error oc-
curred or user constant is
faulty.
○
¢
¢
¢
Overcurrent Overcurrent flowed thorough
the main circuit.
Servopack overheated.
¢
○
¢
¢
Fuse blown Fuse of main circuit power
supply is blown.
○
○
¢
¢
Regenera-
tive error
Failure of regenerative circuit
○
○
¢
¢
Position
error pulse
overflow
The number of pulses in error
counter has exceeded the
preset value.
¢
¢
○
¢
Overvoltage
or undervol-
tage
Main circuit DC voltage is
overvoltage or undervoltage.
○
¢
○
¢
Overspeed
Motor speed has exceeded
the 110% of the maximum al-
lowable speed.
○
○
○
¢
Overload
Motor and Servopack are
overloaded.
¢
¢
¢
¢
Absolute
encoder er-
ror
Absolute encoder is faulty.
¢
¢
¢
¢
Reference
input read
error
Failure of analog voltage ref-
erence input read
○
¢
○
¢
Overrun
Disconnec-
tion of PG
signal line
Overrun occurred due to mo-
tor or encoder signal wiring
faults.
Encoder signal line is discon-
nected.
○ : Output transistor is ON
¢
: Output transistor is OFF
* : Displays an alarm category number.
For details, refer to Appendix E List of Alarm Displays.
3