2 power consumption – Yaskawa DR2 Sigma Servo User Manual
Page 250

SERVO SELECTION AND DATA SHEETS
5.3.2 Power Consumption
238
5.3.2 Power Consumption
Servopack
Output Current
(Effective
Power Loss
W
Power Loss
Type DR2-
(Effective
Value)
A
Main Circuit
Regenerative
Resistor
Control Circuit
Power Loss
W
Supply Voltage
200V
A3Aj
(30W-0.04HP)
0.42
2.9
15.9
A5Aj
(50W-0.07HP)
0.6
4.2
17.2
01Aj
(100W-0.13HP)
0.87
6.3
−
19.3
02Aj
(200W-0.27HP)
2.0
14.5
27.5
04Aj
(400W-0.53HP)
2.6
22.2
6
41.2
08Aj
(750W-1.01HP)
4.4
36.1
6
13
55.1
Supply Voltage
100V
A3Bj
(30W-0.04HP)
0.63
2.9
15.9
A5Bj
(50W-0.07HP)
0.90
4.4
−
17.4
01Bj
(100W-0.13HP)
2.2
12.0
25.0
02Bj
(200W-0.27HP)
2.7
16.2
6
35.2
03Bj
(300W-0.40HP)
3.7
20.1
6
39.1
Note
Power loss of regenerative resistor shows the allowable loss. If this value is exceeded, re-
move the built-in regenerative resistor inside the Servopack and install a resistor externally.
Before installing an external regenerative resistor, contact your Yaskawa representative.
5