7 using dr2 servopack with high voltage line – Yaskawa DR2 Sigma Servo User Manual
Page 174

3.8 Special Wiring
161
2) Connect cables of the same color to each other as shown in the table below. Note that
wiring for incremental and absolute encoders is different.
Signal
Name
Color and Wire Size of
Cable with Connectors
Color and Wire Size of
50-meter Extension
Cable (DP8409179)
PG5V
Red
AWG22
Red
AWG16
PG0V
Black
AWG22
Black
AWG16
FG
Green/Yellow
AWG22
Green/Yellow
AWG16
PA
Blue
AWG26
Blue
AWG26
*
PA
White/Blue
AWG26
White/Blue
AWG26
PB
Yellow
AWG26
Yellow
AWG26
*
PB
White/Yellow
AWG26
White/Yellow
AWG26
PC
Green
AWG26
Green
AWG26
*
PC
White/Green
AWG26
White/Green
AWG26
PS
Violet
AWG26
Purple
AWG26
*
PS
White/Green
AWG26
White/Green
AWG26
RESET
White/Gray
AWG26
White/Gray
AWG26
BAT
Orange
AWG26
Orange
AWG26
BAT0
White/Orange
AWG26
White/Orange
AWG26
3.8.7 Using DR2 Servopack with High Voltage Line
1) DR2 Servopacks are divided into single-phase 200 V and single-phase 100 V types ac-
cording to supply voltage.
If, however, three-phase 400 VAC class (400 V, 440 V) power supply must be used, pre-
pare the following power transformer (for single-phase).
1) 400 or 440 VAC
2) 400 or 440 VAC
200 VAC
100 VAC
3
Only the absolute
encoder can be
connected.