7 forming a protective sequence, 1 using servo alarm output and alarm code output – Yaskawa DR2 Sigma Servo User Manual
Page 141

APPLICATIONS OF Σ-SERIES PRODUCTS
3.7.1 Using Servo Alarm Output and Alarm Code Output
128
3.7
Forming a Protective Sequence
This section describes how to use I/O signals from the Servopack to form a protective
sequence for safety purposes.
3.7.1
Using Servo Alarm Output and Alarm Code Output
128
. . . . . . . . . . . . . . . . . . .
3.7.2
Using Servo ON Input Signal
132
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.3
Using Positioning Complete Signal
133
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.4
Using Speed Coincidence Output Signal
134
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.5
Using Running Output Signal
136
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.6
Using Servo Ready Output Signal
138
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.1 Using Servo Alarm Output and Alarm Code Output
1) Basic Wiring for Alarm Output Signals
Photocoupler Output
Per output:
Maximum operation
voltage: 30 VDC
Maximum output
current: 50 mADC
Open Collector Output
Per output:
Maximum operation
voltage: 30 VDC
Maximum output
current: 20 mADC
Servopack
Photocoupler
I/O power
supply
Host controller
1CN-31
1CN-32
1CN-37
1CN-38
1CN-39
1CN-2
ALM+
ALM-
ALO1
ALO2
ALO3
SG
Provide an external I/O power supply separately. There are no DC power available
from Servopack for output signals.
3