beautypg.com

H3C Technologies H3C S10500 Series Switches User Manual

Page 139

background image

128

Output queue : (Protocol queuing : Size/Length/Discards) 0/500/0

Output queue : (FIFO queuing : Size/Length/Discards) 0/75/0

Last 300 seconds input: 0 bytes/sec, 0 packets/sec

Last 300 seconds output: 0 bytes/sec, 0 packets/sec

0 packets input, 0 bytes

0 input error

0 packets output, 0 bytes

0 output error

Perform the display mpls te tunnel command on each switch to verify information about the MPLS TE
tunnel.

[SwitchA] display mpls te tunnel

LSP-Id Destination In/Out-If Name

1.1.1.1:1 3.3.3.3 -/Vlan1 Tunnel0

[SwitchB] display mpls te tunnel

LSP-Id Destination In/Out-If Name

- - Vlan1/Vlan2 Tunnel0

[SwitchC] display mpls te tunnel

LSP-Id Destination In/Out-If Name

- - Vlan2/- Tunnel0

Perform the display mpls lsp command or the display mpls static-cr-lsp command on each switch to
verify information about the static CR-LSP.

[SwitchA] display mpls lsp

-------------------------------------------------------------------

LSP Information: STATIC CRLSP

-------------------------------------------------------------------

FEC In/Out Label In/Out IF Vrf Name

3.3.3.3/32 NULL/20 -/Vlan1

[SwitchB] display mpls lsp

------------------------------------------------------------------

LSP Information: STATIC CRLSP

------------------------------------------------------------------

FEC In/Out Label In/Out IF Vrf Name

-/- 20/30 Vlan1/Vlan2

[SwitchC] display mpls lsp

------------------------------------------------------------------

LSP Information: STATIC CRLSP

------------------------------------------------------------------

FEC In/Out Label In/Out IF Vrf Name

-/- 30/NULL Vlan1/-

[SwitchA] display mpls static-cr-lsp

total statics-cr-lsp : 1

Name FEC I/O Label I/O If State

Tunnel0 3.3.3.3/32 NULL/20 -/Vlan1 Up

[SwitchB] display mpls static-cr-lsp

total statics-cr-lsp : 1

Name FEC I/O Label I/O If State

Tunnel0 -/- 20/30 Vlan1/Vlan2 Up

[SwitchC] display mpls static-cr-lsp