Configuring protection switching, Configuration prerequisites, Configuration procedure – H3C Technologies H3C S10500 Series Switches User Manual
Page 132
121
To do…
Use the command…
Remarks
Enter the tunnel interface view of
an MPLS TE tunnel
interface tunnel tunnel-number
—
Enable periodic LSP tracert for the
MPLS TE tunnel
mpls te periodic-tracert [ -a
source-ip | -exp exp-value | -h
ttl-value | -m wait-time | -t time-out
| -u retry-attempt ] *
Required
By default, periodic LSP tracert is
disabled for MPLS TE tunnels.
Configure MPLS TE to tear down a
failed RSVP TE tunnel and
reestablish it
mpls te failure-action teardown
Optional
Not configured by default
NOTE:
For more information about the mpls lspv command, see
MPLS Command Reference.
Configuring protection switching
Configuration prerequisites
Before you configure protection switching, complete the following tasks:
•
Configure basic MPLS
•
Enable MPLS TE and create an MPLS TE tunnel
•
Configure BFD for the MPLS TE tunnel.
Before you configure a protection tunnel, prepare the following data:
•
Interface number of the main tunnel in the protection group
•
ID of the protection tunnel in the protection group
Configuration procedure
Follow these steps to configure protection switching:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter tunnel interface view interface tunnel tunnel-number —
Configure a protection
tunnel for the main tunnel
mpls te protection tunnel tunnel-id [ holdoff
holdoff-time | mode { non-revertive | revertive } ] * Required
Configure an external
protection switching action
mpls te protect-switch { clear | force | lock | manual
{ protect-lsp | work-lsp } }
Optional
By default, no switching
action is configured.
Commit the current
configuration of the tunnel
mpls te commit
Required