Centellis 4100 Installation and Use (6806800D82E)
Safety Notes
26
sequence:
First install the RTM, then install the matching AdvancedTCA blade. Otherwise the blades and
RTMs will be damaged.
Blade or System Damage
Installing a blade in the wrong slot causes blade or system damage. Only install blades in the
designated slots.
Damage of RTM and Front Blade
Removing the RTM from the system while the playload of the front blade is powered up may
damage the front blade and RTM.
Whenever removing the RTM from the system, you have to power down the playload of the
front blade first.
RTM
Malfunctioning
Incorrect RTM installation and removal can result in RTM malfunctioning.
When plugging the RTM in or removing it, do not press on the face plate but use the handles.
RTM
Damage
Installing the RTM with other blades than the ones designed for it may damage the RTM and
the front blade.
Only install the RTM with the correct front blade.
Data
Loss
Removing the RTM with the system power on and the blue LED on the front blade still flashing
causes data loss.
Before removing the RTM from a powered system, power down the slot by opening the lower
handle of the front blade and wait until the blue LED is permanently ON.
Blade
Malfunctioning
Incorrect blade installation and removal can result in blade malfunctioning.
Make sure that the blade is connected to the system backplane via all assembled connectors
and that power is available on all zone 1 power pins.
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)