Artesyn Centellis 4100 Installation and Use (2015) User Manual
Page 108

FRU Installation
Centellis 4100 Installation and Use (6806800D82E)
110
Removal Procedure
The following procedure describes how to remove the blade from a system. It assumes that the
system is powered. If the system is unpowered, you can disregards the blue LED and thus skip
the respective step. In that case it is a purely mechanical procedure.
1. Unlatch the lower handle by squeezing the lever and the latch together and turning
the handle outward only enough to unlatch the handle from the face plate. Do not
rotate the handle fully outward.
The blue LED blinks indicating that the blade power-down process is ongoing.
2. Wait until the blue LED is illuminated permanently, then unlatch the upper handle
and rotate both handles fully outward.
3. Remove face plate cables, if applicable.
4. Unfasten the screws of face plate until the blade is detached from shelf.
5. Remove the blade from the shelf.
If the LED continues to blink, a possible reason may be that upper layer software rejects the
blade extraction request.
Data Loss
Removing the blade with the blue LED still blinking causes data loss.
Wait until the blue LED is permanently illuminated, before removing the blade.
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)