Configuring and Operating the System
Centellis 4100 Installation and Use (6806800D82E)
189
The A1 and B1 PEM locations are capable of supplying 90A of current although the PEMs will
only allow for 50A. The A2 and B2 PEM locations are capable of supplying 50A. This allows for
a single PEM in each interconnect to support the full power requirement of the interconnect.
For the blowers, the A1 and B1 feeds are capable of supplying 12A when derated for a 30ºC
temperature rise. For the ShMCs, the A1 and B1 feeds are limited by the 2 mm connector to
approximately 1.5A (per feed).
This manual is related to the following products:
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)