Troubleshooting
Centellis 4100 Installation and Use (6806800D82E)
208
A.1.3
Blower
Error
Possible Reason
Solution
Cooling failure
Blower failed
Check wether blower is placed properly.
Blower failed
Replace blower tray
Airflow is obstructed
Remove obstructing items
Blue LED continues to blink
during removal procedure
Upper layer software rejects
blower extraction request
After insertion, the blue LED does
not come on
Blower defective
Replace blower
Blower not placed properly
Check whether blower is installed
properly
This manual is related to the following products:
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)