beautypg.com

A.1.3 blower, Troubleshooting – Artesyn Centellis 4100 Installation and Use (2015) User Manual

Page 206

background image

Troubleshooting

Centellis 4100 Installation and Use (6806800D82E)

208

A.1.3

Blower

Error

Possible Reason

Solution

Cooling failure

Blower failed

Check wether blower is placed properly.

Blower failed

Replace blower tray

Airflow is obstructed

Remove obstructing items

Blue LED continues to blink
during removal procedure

Upper layer software rejects
blower extraction request

After insertion, the blue LED does
not come on

Blower defective

Replace blower

Blower not placed properly

Check whether blower is installed
properly