Artesyn Centellis 4100 Installation and Use (2015) User Manual
Page 22

Centellis 4100 Installation and Use (6806800D82E)
Safety Notes
24
System
Damage
Environmental contamination can impair system operation.
Locate the system in a stable area free of excess movement and jarring and free of dust, smoke,
and electrostatic discharge (ESD). Make sure that the temperature does not exceed the
operating temperature given in the environmental requirements in this manual and allow
room for proper air flow for cooling.
Personal Injury or System Damage
The system is supplied by a TNV-2 voltage. This voltage is considered hazardous.
Make sure that the external power supply meets the relevant safety standards. Ensure that
TNV-2 is separated from dangerous voltages (mains) through double or reinforced insulation.
System
Overheating
Inproper cooling leads to blade damage.
To ensure proper cooling always operate the system in a horizontal position. Furthermore,
keep clear at least 6 cm adjacent to the cooling vents on the chassis front and back side. For
detailed information refer to
.
Personal or System Damage
Unstable system installation in a rack can cause the rack to topple over.
Therefore, if your system is the only one in the rack, make sure to mount the system in the
lowest part of the rack. If other systems are installed in one rack, start with the heaviest
component at the bottom.
If the rack is equipped with stabilizing devices, make sure that they are installed and extended
so that the rack is secure. Then proceed to mount or service the system.
Personal Injury or System Damage
When pulling the system out of the rack, it can fall down and cause injuries.
Pull out the system cautiously.
Personal Injury or System Damage
The system is heavy and if you carry it on your own you can hurt your back.
To prevent injury, keep your back straight and have two people lift the system or use additional
lifting equipment.
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)