2 node blade installation and removal – Artesyn Centellis 4100 Installation and Use (2015) User Manual
Page 103

FRU Installation
Centellis 4100 Installation and Use (6806800D82E)
105
2. Wait until the blue LEDs on both the front blade and the RTM are permanently ON.
A permanently switched ON LED indicates that the payload of respective blade or
RTM has been powered down.
3. Unlatch the upper handle and rotate both handles fully outward.
4. Remove interface cables from face plate connectors, if applicable.
5. Loosen the two RTM face plate screws.
6. Remove the RTM from the slot.
4.2.2
Node Blade Installation and Removal
Artesyn Embedded Technologies - Embedded Computing node blades are fully compatible
to the AdvancedTCA standard and are designed to be used in AdvancedTCA shelves. They can
be installed in any AdvancedTCA node slot.
This manual is related to the following products:
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)