Configuring and operating the system – Artesyn Centellis 4100 Installation and Use (2015) User Manual
Page 200

Configuring and Operating the System
Centellis 4100 Installation and Use (6806800D82E)
202
The system manager detects a failover because of timeouts of the HPI calls. The system
manager actions depend on network topology.
The system manager performs the following steps:
1. Closes the HPI session
2. Moves its own active virtual IP address to the other interface
3. Reestablishes the HPI session to the active shelf manager with saHpiSessionOpen
4. Waits in saHpiResourcesDiscover until the active shelf manager discovers all
resources.
If a shelf manager failover occurs in a system with IP planes that are connected with one
interlink (between two hubs or between external switches), the system manager can reach the
active shelf manager via the interlink. An IP plane failover is not needed and the connection to
the applications via the same interface as before is kept. If the virtual IP address of the shelf
manager is used, a plane failover is necessary.
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)