Blower trays are mounted in the shelf top. The figure below shows the general airflow for the
Centellis 4100 system.
The cooling system is designed to manage a heat dissipation of 215W per front slot and
additional 25W per rear slot.
The actual cooling performance also depends on the slot population and the heatsink design
of the installed blades and should be validated based on the used system configuration.
Figure 6-9
Shelf Airflow
The distance to other equipment must be sufficient to avoid an overheating of the system.
This manual is related to the following products:
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)