FRU Installation

Centellis 4100 Installation and Use (6806800D82E)

130

11.Once the new PEM is installed and connected, turn on the feed power.

12.If the red LED is ON, the PEM indicates reverse power. Go back to step 8 and

connect the power cables correctly.

PEM Damage
Applying reversal power causes damage to the electrolytic capacitors of the filter.
Therefore, only switch on the breakers if no red light is visible.