Artesyn Centellis 4100 Installation and Use (2015) User Manual
Page 148

FRU Installation
Centellis 4100 Installation and Use (6806800D82E)
150
Replacing Procedure
To replace an air filter, proceed as follows:
1. Find the two tabs on the lower front of the filter frame.
2. Push the tabs toward the rear of the shelf and pull the filter down.
3. Pull the filter carefully toward the front of the shelf to remove.
4. Insert the new filter (with filter frame tabs facing forward and pointing down) by
setting it on the filter guide rails (sloping up toward the rear of the shelf).
5. Grasping the tabs, push the filter into the shelf until it bottoms out.
6. Raise the filter up and into the lower card guide tray and release. The spring fingers
will hold the filter in the proper forward position.
The shelf incorporates two filter sensors. An error will be generated when the shelf is
operating with the filter removed. For a description of the filter sensors refer to the
SPARE/ATCA-A100: Control via IPMI Reference Guide.
Ensure that you insert the matching filter. Therefore, check the revision number at the front
of the filter.
- AXP640 Installation and Use (April 2015) AXP1620 Installation and Use (August 2014) AXP1620 Installation and Use (September 2014) Centellis-4440/AXP-1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (July 2014) AXP1620 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (August 2014) Centellis-4440/AXP-1440 Installation and Use (May 2014) Centellis-4440/AXP1440 Installation and Use (September 2014) AXP640 Installation and Use (May 2014)