Configuring and Operating the System

Centellis 4100 Installation and Use (6806800D82E)

179

IP : 172.16.9.171

Gateway: 172.16.0.170

Submask: 255.255.0.0

*Change out-of-band-address:

shm9s8:~ # hpiship -n 4097 -i 200.200.0.0

Example #2:

Print current shelf address and shelf entity path setting and change shelf address and shelf
entity path settings:

*print current Shelf Address and Shelf Entity Path setting:

shm9s8:~ #hpishaddr

shelf address type=BINARY, length=20: 09 00 00 00 00 00 00 00 00 00

00 00 00 00 00 00 00 00 00 00

shelf id: 9

shelf entity-path: {ADVANCEDTCA_CHASSIS,9}

*change Shelf Address and Shelf Entity Path setting:

shm9s8:~ # hpishaddr -b "0700000000000000000000000000000000000000"

07 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 --

shelf address: 7

shelf entity-path: {ADVANCEDTCA_CHASSIS,7}

6.2.4.1.5 Configuration File

By default, the shelf manager automatically reads the shelf IP connectivity record and
calculates IP addresses based on the described scheme.