beautypg.com

1 non-powered system – Artesyn Centellis 4100 Installation and Use (2015) User Manual

Page 111

background image

FRU Installation

Centellis 4100 Installation and Use (6806800D82E)

113

4.2.3.1

Non-Powered System

This section describes the installation procedure for the ATCA-M100 in non-powered systems.

Installation Procedure

To install an ATCA-M100 in a non-powered shelf, proceed as follows:

1. Put on an ESD wrist strap.

2. Connect the strap to the shelf by attaching the front or rear ESD jack.

3. Insert the board into the shelf by placing the top and bottom edges of the board in

the card guides of the shelf. Ensure that the guiding module of shelf and board are
aligned properly.

4. Slide the board into the shelf by using the ejector ring until you feel resistance.

5. Tighten the screws at the top and the bottom of the board.

Removal Procedure

To remove an ATCA-M100 from a non-powered shelf, proceed as follows:

1. Put on an ESD wrist strap.

2. Connect the strap to the shelf by attaching the front or rear ESD jack.

3. Unfasten the screws of the face plate until the board is detached from the shelf.

Damage of Circuits
Electrostatic discharge and incorrect blade installation and removal can damage circuits or
shorten their life.
Before touching the blade or electronic components, make sure that you are working in an
ESD-safe environment.