Appendix a, Specifications, Allations. refer to – Rockwell Automation 20D PowerFlex 700H and 700S Frame 9-14 Drives Installation - A4 Size User Manual
Page 175: Appendix

Appendix
A
Specifications
Category
PowerFlex 700H
PowerFlex 700S
Agency
Certification
Listed to UL508C and CAN/CSA-C2.2 No. 14-M91.
UL and cUL Listed to UL508C and CAN/CSA - 22.2 No. 14-95.
Marked for all applicable European Directives
(1)
EMC Directive (89/336/EEC)
EN 61800-3 Adjustable Speed electrical power drive systems
Low Voltage Directive (73/23/EEC)
EN 50178 Electronic Equipment for use in Power Installations
Marked for all applicable European Directives
EMC Directive (89/336/EEC)
Emissions:
EN 61800-3 Adjustable Speed electrical power drive systems Part 3
Low Voltage Directive (73/23/EEC)
EN 50178 Electronic Equipment for use in Power Installations
Certified to AS/NZS, 1997 Group 1, Class A.
Certified to AS/NZS, 1997 Group 1, Class A.
Certified to ATEX directive 94/9/EC. Group II Category (2) GD
Applications with ATEX Approved Motors. Refer to Appendix E -
for more
information.
Certified to ATEX directive 94/9/EC. Group II Category (2) GD Applications
with ATEX Approved Motors. PowerFlex 700S Phase II Control drives only.
Refer to publication 20D-UM006… for more information.
NA
TUV functional safety report only (no FS mark on the label)
The drive is also designed to meet the following specifications:
NFPA 70 - US National Electrical Code
NEMA ICS 7.1 - Safety standards for Construction and Guide for
Selection, Installation and Operation of Adjustable Speed Drive
Systems.
IEC 146 - International Electrical Code.
The drive is designed to meet applicable requirements of the following
codes/standards:
IEC 61800-2 Adjustable speed electrical power drive systems - General
requirements
IEC 61800-5-1 Adjustable speed electrical power drive systems - Safety
requirements
NFPA 70 - US National Electrical Code
(1)
Applied noise impulses may be counted in addition to the standard pulse train causing erroneously high [Pulse Freq] readings.
N223
II 2 G/D
TUV
Rheinland
Product Safety
.
.
Production inspected
W
E
C
TUV
Rheinland
.
.
Functional
Safety
Bauart geprüft
Type approved
EN 50178
Category
Specification
PowerFlex 700H
PowerFlex 700S
Protection
Drive
380/400V
480V
500V
600V
690V
380/400V
480V
500V
600V
690V
AC Input Overvoltage Trip:
611Vac
611Vac
611Vac
806Vac
806Vac
675Vac
675Vac
675Vac
889Vac
889Vac
AC Input Undervoltage Trip:
235Vac
235Vac
235Vac
326Vac
326Vac
Adjustable
Bus Overvoltage Trip:
911Vdc
911Vdc
911V dc
1200V dc
1200V dc
911Vdc
911Vdc
911Vdc
1200Vdc
1200Vdc
Bus Undervoltage Shutoff/Fault:
333Vdc
333Vdc
333Vdc
461Vdc
461Vdc
Adjustable
Nominal Bus Voltage (Full Load):
517Vdc
621Vdc
645Vdc
776Vdc
890Vdc
540Vdc
648Vdc
645Vdc
810Vdc
931V dc
Heat Sink Thermistor:
Monitored by microprocessor overtemp trip
Monitored by microprocessor overtemp trip
Drive Overcurrent Trip
Software Overcurrent Trip:
Hardware Overcurrent Trip:
Instantaneous Current Limit:
—
360% of rated Heavy Duty current (typical)
—
Calculated value, 105% of motor rated to 200% of drive rated
360% of rated Heavy Duty current (typical)
—
Line transients:
up to 6000 volts peak per IEEE C62.41-1991
Up to 6000 volts peak per IEEE C62.41-1991
Control Logic Noise Immunity:
Showering arc transients up to 1500V peak
Showering arc transients up to 1500V peak
Power Ride-Thru:
15 milliseconds at full load
15 milliseconds at full load
Logic Control Ride-Thru:
0.5 seconds minimum, 2 seconds typical
0.25 seconds, drive not running
Ground Fault Trip:
Phase-to-ground on drive output
Phase-to-ground on drive output
Short Circuit Trip:
Phase-to-phase on drive output
Phase-to-phase on drive output