beautypg.com

Rockwell Automation 20D PowerFlex 700H and 700S Frame 9-14 Drives Installation - A4 Size User Manual

Page 204

background image

B-8

Lifting and Mounting Instructions

Table B.F Frames 10 - 12 Open Type Drives - Approximate Weights

Table B.G Frame 13 Open Type Drives - Approximate Weights

Table B.H Frame 14 Open Type Drives - Approximate Weights

Frame
Size

Drive
Voltage
Class

Drive
Rating
Amps

Power Structure
Weight
kg (lbs.)

AC Choke Weight kg
(lbs.)

AC Input Drive &
Packaging Weight
kg (lbs.)

(4)

(4)

DC input drive and packaging weight is equal to the weight of the power structure(s)

10

400

385

120 (265)

115 (254)

235 (519)

460

120 (265)

115 (254)

235 (519)

500

120 (265)

115 (254)

235 (519)

600

261

120 (265)

53 (117)

173 (382)

325

120 (265)

84 (185)

204 (450)

385

120 (265)

84 (185)

204 (450)

416

120 (265)

84 (185)

204 (450)

11

400

590

210 (463)

84 (185)

(2)

(2)

Two AC chokes are required for this frame 11 AC Drive

378 (833)

650

210 (463)

84 (185)

(2)

378 (833)

730

210 (463)

84 (185)

(2)

378 (833)

600

460

210 (463)

115 (254)

325 (717)

502

210 (463)

115 (254)

325 (717)

590

210 (463)

115 (254)

(2)

440 (970)

12

400

820

120 (265)

(1)

(1)

Two power structures are required per frame 12 Drive

115 (254)

(3)

(3)

Two AC chokes are required per frame 12 AC Drive

350 (772)

920

120 (265)

(1)

115 (254)

(3)

350 (772)

1030

120 (265)

(1)

115 (254)

(3)

350 (772)

600

650

120 (265)

(1)

84 (185)

(3)

288 (635)

750

120 (265)

(1)

84 (185)

(3)

288 (635)

820

120 (265)

(1)

84 (185)

(3)

288 (635)

Drive
Voltage
Class

Drive
Rating
Amps

Power Module Weight kg
(lbs.)

AC Choke Weight
kg (lbs.)

NFE Module Weight
kg (lbs.)

400

1150

306 (675)

130 (287)

(1)

(1)

Two AC chokes and NFE (Non-Regenerative Front-End) Modules are required for this frame 13 AC drive

67 (148)

(1)

1300

306 (675)

115 (254)

(2)

(2)

Three AC chokes and NFE Modules are required for this frame 13 AC drive

67 (148)

(2)

1450

306 (675)

115 (254)

(2)

67 (148)

(2)

600

920

306 (675)

130 (287)

(1)

67 (148)

(1)

1030

306 (675)

130 (287)

(1)

67 (148)

(1)

1180

306 (675)

130 (287)

(1)

67 (148)

(1)

Drive
Voltage
Class

Drive
Rating
Amps

Power Module
Weight
kg (lbs.)

AC Choke
Weight kg (lbs.)

NFE Module
Weight
kg (lbs.)

Output Reactor
(du/dt Filter)
kg (lbs.)

(4)

(4)

Two du/dt filters are required per frame 14 AC drive

400

1770

306 (675)

115 (254)

(1)

(1)

Four AC chokes and NFE Modules are required for this frame 14 AC drive

67 (148)

(1)

160 (353)

2150

306 (675)

130 (287)

(1)

67 (148)

(1)

160 (353)

2700

306 (675)

115 (254)

(2)

(2)

Six AC chokes and NFE Modules are required for this frame 14 AC drive

67 (148)

(2)

160 (353)

600

1500

306 (675)

115 (254)

(3)

(3)

Three AC chokes and NFE Modules are required for this frame 14 AC drive

67 (148)

(3)

120 (265)

1900

306 (675)

115 (254)

(1)

67 (148)

(1)

160 (353)

2250

306 (675)

130 (287)

(1)

67 (148)

(1)

160 (353)

This manual is related to the following products: