Rockwell Automation 20D PowerFlex 700H and 700S Frame 9-14 Drives Installation - A4 Size User Manual
Page 204

B-8
Lifting and Mounting Instructions
Table B.F Frames 10 - 12 Open Type Drives - Approximate Weights
Table B.G Frame 13 Open Type Drives - Approximate Weights
Table B.H Frame 14 Open Type Drives - Approximate Weights
Frame
Size
Drive
Voltage
Class
Drive
Rating
Amps
Power Structure
Weight kg (lbs.)
AC Choke Weight kg
(lbs.)
AC Input Drive &
Packaging Weight
kg (lbs.)
(4)
(4)
DC input drive and packaging weight is equal to the weight of the power structure(s)
10
400
385
120 (265)
115 (254)
235 (519)
460
120 (265)
115 (254)
235 (519)
500
120 (265)
115 (254)
235 (519)
600
261
120 (265)
53 (117)
173 (382)
325
120 (265)
84 (185)
204 (450)
385
120 (265)
84 (185)
204 (450)
416
120 (265)
84 (185)
204 (450)
11
400
590
210 (463)
84 (185)
(2)
(2)
Two AC chokes are required for this frame 11 AC Drive
378 (833)
650
210 (463)
84 (185)
(2)
378 (833)
730
210 (463)
84 (185)
(2)
378 (833)
600
460
210 (463)
115 (254)
325 (717)
502
210 (463)
115 (254)
325 (717)
590
210 (463)
115 (254)
(2)
440 (970)
12
400
820
120 (265)
(1)
(1)
Two power structures are required per frame 12 Drive
115 (254)
(3)
(3)
Two AC chokes are required per frame 12 AC Drive
350 (772)
920
120 (265)
(1)
115 (254)
(3)
350 (772)
1030
120 (265)
(1)
115 (254)
(3)
350 (772)
600
650
120 (265)
(1)
84 (185)
(3)
288 (635)
750
120 (265)
(1)
84 (185)
(3)
288 (635)
820
120 (265)
(1)
84 (185)
(3)
288 (635)
Drive
Voltage
Class
Drive
Rating
Amps
Power Module Weight kg
(lbs.)
AC Choke Weight
kg (lbs.)
NFE Module Weight
kg (lbs.)
400
1150
306 (675)
130 (287)
(1)
(1)
Two AC chokes and NFE (Non-Regenerative Front-End) Modules are required for this frame 13 AC drive
67 (148)
(1)
1300
306 (675)
115 (254)
(2)
(2)
Three AC chokes and NFE Modules are required for this frame 13 AC drive
67 (148)
(2)
1450
306 (675)
115 (254)
(2)
67 (148)
(2)
600
920
306 (675)
130 (287)
(1)
67 (148)
(1)
1030
306 (675)
130 (287)
(1)
67 (148)
(1)
1180
306 (675)
130 (287)
(1)
67 (148)
(1)
Drive
Voltage
Class
Drive
Rating
Amps
Power Module
Weight kg (lbs.)
AC Choke
Weight kg (lbs.)
NFE Module
Weight kg (lbs.)
Output Reactor
(du/dt Filter)
kg (lbs.)
(4)
(4)
Two du/dt filters are required per frame 14 AC drive
400
1770
306 (675)
115 (254)
(1)
(1)
Four AC chokes and NFE Modules are required for this frame 14 AC drive
67 (148)
(1)
160 (353)
2150
306 (675)
130 (287)
(1)
67 (148)
(1)
160 (353)
2700
306 (675)
115 (254)
(2)
(2)
Six AC chokes and NFE Modules are required for this frame 14 AC drive
67 (148)
(2)
160 (353)
600
1500
306 (675)
115 (254)
(3)
(3)
Three AC chokes and NFE Modules are required for this frame 14 AC drive
67 (148)
(3)
120 (265)
1900
306 (675)
115 (254)
(1)
67 (148)
(1)
160 (353)
2250
306 (675)
130 (287)
(1)
67 (148)
(1)
160 (353)