background image

4-16

Installation and Hookup

Publication 999-122 - January 1997

Connecting RS-232 Devices

When an IMC-S/23x serial port is configured for RS-232 operation (see
Configuring the IMC-S/23x earlier in this section), RS-232C
compatible serial communications devices may be connected to it using
readily-available RS-232C cables. To prevent damage to the
IMC-S/23x or the serial device, make sure that the serial port is
configured for RS-232 operation before connecting RS-232 compatible
devices.

The pinout of each serial port is identical and shown for reference in
the table below.

Note that the hardware handshaking signals (RTS/CTS and DSR/DTR)
for both serial ports are jumpered inside the IMC-S/23x. This allows
the use of standard RS-232C cables with serial devices which require
hardware handshaking.

!

ATTENTION: Configure the serial port for RS-232
operation before connecting RS-232 compatible devices.

IMC-S/23x RS-232 Serial Port Pinout

DB-9 Pin

Signal

Description

1
2
3
4
5
6
7
8
9

-

TxD

RxD

DTR
Com
DSR

RTS
CTS

N/C

Do Not Connect
Transmitted Data
Received Data
Data Terminal Ready
Signal Common
Data Set Ready
Ready To Send
Clear To Send
No Connection