MacDon M205 Operators Manual User Manual
Page 461

J1939
SPN
J1939
FMI
Lamp
Color
Cummins
Code
J1939
SPN
Cummins
Description
Category
CDM Error
Message
629
12
Red
111
Controller #1
Engine control module
critical internal failure -
bad intelligent device or
component
Controller #1
2
Amber
341
527
Calibration
Memory
Engine control module
data lost - Data erratic,
intermittent, or incorrect
13
Red
342
Electronic calibration code
incompatibility - Out of
calibration
630
31
Amber
2217
ECM program memory
(RAM) corruption -
Condition exists
Calibration
Memory
631
2
415
415
Engine
Software
Data incorrect
Engine
software
633
31
Amber
2311
Fuel Control
Valve #1
Fueling actuator #1 circuit
error - Condition exists
Fuel Control
Valve #1
637
11
143
143
Primary To
Secondary
Speed Signal
Calibration fault
Primary to
secondary
speed signal
9
Amber
285
247
SAE J1939 multiplexing
PGN timeout error -
Abnormal update rate
639
13
Amber
286
SAE J1939
Datalink
SAE J1939 multiplexing
configuration error - Out of
calibration
SAE J1939
Datalink
1484
31
None
211
J1939 Error
Additional auxiliary
diagnostic codes logged -
Condition exists
J1939 Error
3
Amber
2385
VGT actuator driver circuit
- Voltage above normal, or
shorted to high source
641
4
Amber
2384
Variable
Geometry
Turbocharger
VGT actuator driver circuit
- Voltage below normal, or
shorted to low source
Variable
Geometry
Turbocharger
5
177
526
Solenoid current low
646
6
177
526
Turbo
Wastegate
Solenoid current high
Turbo
Wastegate
169887
445
Revision A