8electrical system, Preventing electrical system damage, Battery – MacDon M205 Operators Manual User Manual
Page 366: Maintaining the battery, Electrical system, Preventing electrical system damage battery, 8 electrical system, Caution
![background image](/manuals/570509/366/background.png)
5.7.8
Electrical System
Preventing Electrical System Damage
To prevent electrical system damage, take the following
precautions:
• Carefully
observe
polarity
when
attaching
booster battery.
• Do NOT short across battery or alternator terminals,
or allow battery positive (+) cable or alternator wire to
become grounded.
• Be sure alternator connections are correct before cables
are connected to battery.
• When welding on any part of the machine, disconnect
battery cables and alternator wire. Refer to
.
• Always disconnect battery ground cable when working
with the alternator or regulator.
• Never attempt to polarize alternator or regulator.
• If wires are disconnected from the alternator, use the
illustration to ensure proper reconnection.
• Never ground the alternator field terminal or field.
• Never connect or disconnect alternator or regulator
wires with battery connected or alternator operating.
• Always disconnect cables from the battery when using
a charger to charge battery in windrower.
• Ensure all cables are securely connected before
operating engine.
Figure 5.132: Alternator
A - Negative Terminal
B - Positive Terminal
Battery
Maintaining the Battery
CAUTION
Do NOT attempt to service battery unless you have the proper equipment and experience to perform the
job. Have it done by a qualified Dealer.
• Check battery charge once a year, more often if operating in cold weather. Hydrometer readings should be
1.260 to 1.300. Readings below 1.250 indicate charging is required. Refer to
Charging the Battery, page 352
.
Add electrolyte if necessary. Refer to
Adding Electrolyte to the Battery, page 354
.
• Keep batteries clean by wiping with a damp cloth.
• Keep all connections clean and tight. Remove any corrosion and wash terminals with a solution of baking soda
and water. A light coating of grease on terminals (after cables are attached) will reduce corrosion.
• To prolong battery life, store batteries fully charged and at +20° to +80°F (-7° to +26°C). Check voltage after
storage and recharge as needed according to battery and charger manufacturer recommendations.