Caution – MacDon M205 Operators Manual User Manual
Page 153
![background image](/manuals/570509/153/background.png)
3. Press SELECT (B) until DIAGNOSTIC MODE? is
displayed in upper line.
• NO/YES is displayed on the lower line.
4. Press right (A) arrow to select Yes. Press SELECT (B).
Figure 3.189: Selecting Diagnostic Functions
5. Press SELECT (B) until ACTIVATE FUNCTIONS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
6. Press right (A) arrow to select YES. Press SELECT (B).
• ACTIVATE HEADER HT is displayed on the
upper line.
Figure 3.190: Selecting Activate Functions
CAUTION
Check to be sure all bystanders have cleared the area.
7. Press SELECT (B) until DRAPER DRV SPD XXXX is
displayed on the upper line.
IMPORTANT:
Do NOT over speed the draper drive.
8. Press and hold HAZARD (C) button.
• Press left (B) arrow to decrease draper drive speed.
• Press right (D) arrow to increase draper
drive speed.
Verify the draper drive is functioning properly.
9. Release the HAZARD (C) button. The draper drive
will stop.
Figure 3.191: Activating Draper Drive
10. Press
PROGRAM
(A)
to
exit
Programming
Mode or press SELECT (E) to proceed to next
ACTIVATE FUNCTION.
169887
137
Revision A