1. Turn ignition key to RUN, or start the engine. Refer to
.
2. Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER SETUP? is displayed on the
upper line.
• NO/YES is displayed on the lower line.
3. Press right (B) arrow to select YES. Press SELECT (C).
• SET KNIFE SPEED? is displayed.
Figure 3.101: CDM Programming Buttons
4. Press SELECT (D) until OVERLOAD PRESSURE? is
displayed on the upper line.
• The current overload pressure is displayed on
lower line.
NOTE:
Pressure range is 2500–5000 psi.
5. Press left (B) or right (C) arrows to set hydraulic
overload pressure. Press SELECT (D).
6. Press PROGRAM (A) to exit Programming Mode or
press SELECT (D) to proceed to next WINDROWER
SETUP action.
Figure 3.102: Setting Hydraulic Overload
Pressure