3. Press SELECT (B) until DIAGNOSTIC MODE? is
displayed in upper line.
• NO/YES is displayed on the lower line.
4. Press right (A) arrow to select Yes. Press SELECT (B).
Figure 3.201: Selecting Diagnostic Functions
5. Press SELECT (B) until ACTIVATE FUNCTIONS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
6. Press right (A) arrow to select YES. Press SELECT (B).
• ACTIVATE HEADER HT is displayed on the
upper line.
Figure 3.202: Selecting Activate Functions
7. Press SELECT (E) until ACTIVATE DWA DRV is
displayed on the upper line.
CAUTION
Check to be sure all bystanders have cleared the area.
IMPORTANT:
Do NOT over speed the DWA drive.
8. Press and hold HAZARD (C) button.
• Press left (B) arrow to decrease DWA drive speed.
• Press right (D) arrow to increase DWA drive speed.
Verify the DWA drive is functioning properly.
9. Release the HAZARD (C) button. The DWA drive
will stop.
10. Press PROGRAM (A) to exit Programming Mode or
press SELECT (E) to proceed to next ACTIVATE
FUNCTION.
Figure 3.203: Activating DWA Drive