MacDon M205 Operators Manual User Manual
Page 458

J1939
SPN
J1939
FMI
Lamp
Color
Cummins
Code
J1939
SPN
Cummins
Description
Category
CDM Error
Message
1
Red
598
Alternate
Potential
(Voltage)
Electrical charging system
voltage low - Data valid but
below normal operational
range - Most severe level
16
Amber
596
Electrical charging
system voltage high -
Data valid but above
normal operational range
- Moderately severe level
167
18
Amber
597
Electrical charging system
voltage low - Data valid but
below normal operational
range - Moderately severe
level
Alternator
Potential
(Voltage)
0
422
422
Excessive battery power
1
Low battery power
2
ECM Battery
Power
Intermittent
16
Amber
442
Electrical
Potential
(Voltage)
Battery #1 voltage high
- Data valid but above
normal operational range
- Moderately severe level
168
18
Amber
441
Electrical
Potential
(Voltage)
Battery #1 voltage low
- Data valid but below
normal operational range
- Moderately severe level
ECM Battery
Power
3
Amber
249
Ambient air temperature
sensor circuit - Voltage
above normal, or shorted
to high source
171
4
Amber
256
Ambient Air
Temperature
Ambient air temperature
sensor circuit - Voltage
below normal, or shorted
to low source
Ambient Air
Temperature
173
15
Amber
185
High Exhaust
Temperature
High exhaust temperature
Exhaust
Temp
169887
442
Revision A