7calibrating the header sensors, Calibrating the header height sensor, Calibrating the header sensors – MacDon M205 Operators Manual User Manual
Page 107: 7 calibrating the header sensors

5. Press SELECT (D) until DISPLAY CONTRAST is
displayed on the upper line.
• Default setting is displayed on the lower line.
6. Press left (B) or right (C) arrows to adjust
display contrast.
7. Press PROGRAM (A) to exit Programming Mode or
press SELECT (D) to proceed to next CAB DISPLAY
SETUP? action.
Figure 3.82: Adjusting Display Contrast
3.18.7
Calibrating the Header Sensors
Sensor calibration programs the windrower control module (WCM) with settings for the attached header.
Calibrating the Header Height Sensor
NOTE:
• Header MUST be attached to the windrower to perform this procedure. The cab display module (CDM)
automatically adjusts its programming for each header. For more information, refer to
.
• Engine MUST be running to perform this procedure.
1. Start the engine. Refer to
.
2. Press PROGRAM (A) and SELECT (C) on cab display
module (CDM) to enter Programming Mode.
• WINDROWER SETUP? is displayed on the
upper line.
3. Press SELECT (C) until CALIBRATE SENSORS? is
displayed on the upper line.
• NO/YES is displayed on the lower line.
Figure 3.83: CDM Programming Buttons
169887
91
Revision A