beautypg.com

Snmp-server v3-host – Allied Telesis AT-S95 CLI User Manual

Page 211

background image

SNMP Commands

Page 199

Parameters

ip-address—Specifies the IP address of the host (targeted recipient).

hostname—Specifies the name of the host. (Range:1-158 characters)

community-string—Specifies a password-like community string sent with the notification operation.

(Range: 1-20)

traps—Indicates that SNMP traps are sent to this host. If unspecified, SNMPv2 traps are sent to the host.

informs—Indicates that SNMP informs are sent to this host. Not applicable to SNMPv1.

1—Indicates that SNMPv1 traps will be used.

2—Indicates that SNMPv2 traps will be used. If

port—Specifies the UDP port of the host to use. If unspecified, the default UDP port number is 162.

(Range:1-65535)

filtername—Specifies a string that defines the filter for this host. If unspecified, nothing is filtered.

(Range: 1-30 characters)

seconds—Specifies the number of seconds to wait for an acknowledgment before resending informs. If

unspecified, the default timeout period is 15 seconds. (Range: 1-300)

retries—Specifies the maximum number of times to resend an inform request. If unspecified, the default

maximum number of retries is 3. (Range: 0-255)

Default Configuration

This command has no default configuration.

Command Mode

Global Configuration mode

User Guidelines

When configuring an SNMPv1 or SNMPv2 notification recipient, a notification view for that recipient is
automatically generated for all the MIB.

When configuring an SNMPv1 notification recipient, the Inform option cannot be selected.

If a trap and inform are defined on the same target, and an inform was sent, the trap is not sent.

Example

The following example enables SNMP traps for host 10.1.1.1 with community string "management" using
SNMPv2.

snmp-server v3-host

The snmp-server v3-host Global Configuration mode command specifies the recipient of Simple Network
Management Protocol Version 3 notifications. Use the no form of this command to remove the specified host.

Syntax

snmp-server v3-host {ip-address | hostname} username [traps | informs] {noauth | auth | priv} [udp-port port]
[filter
filtername] [timeout seconds] [retries retries]

no snmp-server host {ip-address | hostname} username [traps | informs]

Console(config)# snmp-server host 10.1.1.1 management 2