The following table describes significant fields shown above:

show rmon alarm

The show rmon alarm User EXEC mode command displays alarm configuration.

Syntax

show rmon alarm number

Parameters

number — Specifies the alarm index. (Range: 1 - 65535)

Default Configuration

This command has no default configuration.

Command Mode

User EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays RMON 1 alarms.

Field

Description

Index

An index that uniquely identifies the entry.

OID

Monitored variable OID.

Owner

The entity that configured this entry.

Console> show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI