beautypg.com

Show rmon alarm-table – Allied Telesis AT-S95 CLI User Manual

Page 197

background image

RMON Commands

Page 185

Command Mode

Global Configuration mode

User Guidelines

There are no user guidelines for this command.

Example

The following example configures the following alarm conditions:

Alarm index — 1000

Variable identifier — ati

Sample interval — 360000 seconds

Rising threshold — 1000000

Falling threshold — 1000000

Rising threshold event index — 10

Falling threshold event index — 20

show rmon alarm-table

The show rmon alarm-table User EXEC mode command displays the alarms table.

Syntax

show rmon alarm-table

Default Configuration

This command has no default configuration.

Command Mode

User EXEC mode

User Guidelines

There are no user guidelines for this command.

Example

The following example displays the alarms table.

Console(config)# rmon alarm 1000 ati 360000 1000000 1000000 10 20

Console> show rmon alarm-table

Index

OID

Owner

-----

----------------------

-------

1

1.3.6.1.2.1.2.2.1.10.1

CLI

2

1.3.6.1.2.1.2.2.1.10.1

Manager

3

1.3.6.1.2.1.2.2.1.10.9

CLI