beautypg.com

HP XP Command View Advanced Edition Software User Manual

Page 303

background image




Troubleshooting



303

Table 6-1

General troubleshooting information

Problem Cause

Recommended

Action

The following error message is
displayed and the operation of
Device Manager CLI is
stopped:

An unspecified error
was encountered in CLI.

Collect the following information, and
then contact your HP technical support
representative.

CLI log file

CLI property file

Contents entered on the command
line

An executed batch file if a batch
was executed.

Device Manager server log.

Text is omitted from the
displayed error message.

CAUSE: A maximum of 256
characters can be displayed for
the main body of an error
message.

Check the omitted contents in the CLI
log file.

An error message that includes
the following character is
displayed when a command of
Device Manager CLI is
executed:

user group

CAUSE: The settings related to
the resource group might not be
correct.

Check the settings related to the
resource group, and then re-execute the
command.

The following message is
displayed when a Device
Manager CLI command is
executed:

[KAIC07472-E]

Subsystem

information

is not

consistent.

Perform a

refresh

of the

subsystem,

and then try

again.

CAUSE: The configuration in the
Device Manager database is
inconsistent with the configuration
of the actual storage subsystem
information.

Use the AddStorageArray command
to refresh the storage subsystem
information. Verify that the value of
statusOfDBInconsistency

indicated below An instance of
StorageArray

in the command

execution results is 0, and then re-
execute the command.