beautypg.com

HP XP Command View Advanced Edition Software User Manual

Page 110

background image




Command line interface commands



110

Table 4-38

GetStorageArray (subtarget=HostStorageDomain) command parameters

Parameter Name

Status

Description

domain

Optional

Domain ID of the host storage domain
If you omit this parameter, all the host storage domains become the
target. If you specify this parameter, you must also specify the model and
serialnum

parameters. This parameter can be specified in decimal and

hexadecimal. If you specify a hexadecimal number, add the 0x prefix.

NOTE:

The execution results are output in decimal.

NOTE:

If you specify this parameter, you must also specify the port or

portname

parameter. If neither is specified, this parameter will be

ignored.

NOTE:

Do not specify domain and domainnickname at the same time,

as this might cause an error to occur.

domainnickname

Optional
(for
XP24000/
XP20000,
XP12000/
XP10000/
SVS200,
and
XP1024/
XP128)

Nickname of the host storage domain
If you omit this parameter, all the host storage domains become the
target.

NOTE:

If you this parameter, you must specify the port or portname

parameter. If neither is specified, this parameter will be ignored.

NOTE:

Do not specify domain and domainnickname at the same time,

as this might cause an error to occur.

hsdsubinfo

Optional

Specific information about the host storage domain

The values you can specify are WWN, Path, and FreeLUN. If you specify
multiple values at the same time, separate the values by commas.

port

Optional

Number of the port containing the host storage domain

If port and portname are omitted, information about all ports is
displayed. If you specify this parameter, you must also specify the model
and serialnum parameters.

NOTE:

If you specify this parameter, you must specify the domain or

domainnickname

parameter. If neither is specified, this parameter will

be ignored.

NOTE:

Do not specify port and portname at the same time, as this may

might cause an error to occur.

portname

Optional

Port name of the host storage domain

If port and portname are omitted, information about all ports is
displayed. If you specify this parameter, you must also specify the model
and serialnum parameters.

NOTE:

If you specify this parameter, you must specify the domain or

domainnickname

parameter. If neither is specified, this parameter will

be ignored.

NOTE:

Do not specify port and portname at the same time, as this may

might cause an error to occur.