HP XP Command View Advanced Edition Software User Manual
Page 215
![background image](/manuals/397820/215/background.png)
Command line interface commands
215
Table 4-97
AddReplication command parameters
Parameter Name
Status
Description
pvolpoolid
Optional
Specify the pool ID of the journal data to which P-VOL belongs.
NOTE:
You must specify this parameter when you are using method 2 or
3 with XP Continuous Access Journal Software.
NOTE:
When you are using method 1, this parameter value is invalid
even if you specify a value.
svolarraytype
Required
Specify the model of the storage subsystem that contains S-VOL.
svolserialnum
Required
Specify the serial number of the storage subsystem that contains S-VOL.
svoldevnum
Required
Specify the device number of S-VOL.
This parameter can be specified in decimal, and in colon-separated
hexadecimal. If you specify a hexadecimal number, for
XP12000/XP10000/SVS200, XP1024/XP128, and XP512/XP48, use the
xx:yy format, where xx is the CU number, and yy is the LDEV number.
For XP24000/XP20000, use the ww:xx:yy format, where ww is the
LDKC number, xx is the CU number, and yy is the LDEV number. ww is
optional. If you omit ww, the LDKC number is regarded as 0.
NOTE:
The execution results are output in decimal.
svolportid
Optional
Specify the port ID in the HORCM configuration file that manages S-VOL
paths.
NOTE:
If you specify this parameter, specify either svolportid or
svolportname
. Do not specify both parameters at the same time. This
might cause an error to occur.
svolportname
Optional
Specify the port name in the HORCM configuration file that manages the
S-VOL paths.
NOTE:
If you specify this parameter, specify either svolportid or
svolportname
. Do not specify both parameters at the same time. This
might cause an error to occur.
svolpoolid
Optional
Specify the pool ID of the journal data to which S-VOL belongs.
NOTE:
You must specify this parameter when you are using method 2 or
3 with XP Continuous Access Journal Software.
NOTE:
When you are using method 1, this parameter value is invalid
even if you specify a value.
replicationfunct
ion
Optional
Specify the type of operation that is to be executed with the copy pair:
BusinessCopy
: Execute XP Business Copy Software.
ContinuousAccessSync
: Execute XP Continuous Access
Synchronous Software.
ContinuousAccessAsync
: Execute XP Continuous Access
Asynchronous Software.
Snapshot
: Execute XP Snapshot.
ContinuousAccessJournal
: Execute XP Continuous Access
Journal Software.
For the XP24000/XP20000, XP12000/XP10000/SVS200,
XP1024/XP128, XP512/XP48:
The default value is as follows:
•
When P-VOL and S-VOL are located in the same storage
subsystem: BusinessCopy
•
When P-VOL and S-VOL are located in different storage
subsystems: ContinuousAccessAsync