4-17-4 getstoragearray (subtarget=commparameters) – HP XP Command View Advanced Edition Software User Manual
Page 101
Command line interface commands
101
autoLunCapacity=0
onDemandCapacity=0
totalFreeSpace=3,223,296
largestFreeSpace=1,545,984
substance=0
slprNumber=-1
clprNumber=-1
openTotalCapacity=209,638,800
openAllocatedCapacity=192,256,560
openFreeCapacity=17,382,240
openAutoLunCapacity=0
openOnDemandCapacity=0
imTotalCapacity=0
imAllocatedCapacity=0
imFreeCapacity=0
imAutoLunCapacity=0
imOnDemandCapacity=0
mfTotalCapacity=0
mfAutoLunCapacity=0
mfOnDemandCapacity=0
mfAllocatedCapacity=0
mfUnallocatedCapacity=0
openAllocatedActualCapacity=192,256,560
openUnallocatedCapacity=17,382,240
openUnallocatedActualCapacity=17,382,240
openReservedCapacity=0
openReservedActualCapacity=0
type=0
*****
: The value is encoded by the CLI.
4-4-17-4 GetStorageArray (subtarget=commparameters)
GetStorageArray (subtarget=Commparameters)
obtains information about how to access
one or all storage subsystems (see parameters in
A user to whom a user-defined resource group is assigned can obtain information about how
to access storage subsystems that the user is permitted to access.
Table 4-34
GetStorageArray (subtarget=commparameters) command parameters
Parameter Name Status
Description
model
Optional
Model of the storage subsystem
If you omit this parameter, you will obtain information about the models of
all storage subsystems.
serialnum
Optional
Serial number of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
subtarget
Required
Specify Commparameters.
Command execution example: In this example, the CLI command obtains information about how
to access a storage subsystem (serial number: 10001, model: XP1024).
hdvmcli GetStorageArray -o "D:\logs\XP1024 GetStorageArray_CommParameters.log"
subtarget=CommParameters model=XP1024 serialnum=10001