Section – HP XP Command View Advanced Edition Software User Manual
Page 137
![background image](/manuals/397820/137/background.png)
Command line interface commands
137
Command execution result 2:
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 PortController elements:
An instance of PortController
objectID=*****
cluster=1
card=1
controllerID=1
displayName=CHA-1P
mode=1
type=12
*****
: The value is encoded by the CLI.
4-4-17-18 GetStorageArray (subtarget=ReplicationInfo)
GetStorageArray (subtarget=ReplicationInfo)
obtains the information about replication
performed by one or all storage subsystems (see parameters in
A user to whom a user-defined resource group is assigned can obtain replication information about
logical units for which the user has permission. If both a logical unit that is allowed and a logical unit
that is not allowed exist, the object ID for the volume of the logical unit that is not allowed is
displayed as
n/a.
NOTE:
For XP24000/XP20000 and XP12000/XP10000/SVS200, the partitioned storage
administrator cannot obtain all the information about paired volumes and external volumes.
NOTE:
For XP24000/XP20000, if there is information about copy pairs consisting of mainframe
volumes, microcode version 60-01-6x-xx/xx or later is required. When using an older microcode
version and obtaining copy pair information, the information about copy pairs consisting of
mainframe volumes is output as the information about copy pairs consisting of open volumes.
Table 4-48
GetStorageArray (subtarget=ReplicationInfo) command parameters
Parameter Name
Status
Description
model
Optional
Model of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
serialnum
Optional
Serial number of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
subtarget
Required
Specify ReplicationInfo.
objectid
Optional
Object ID of the replication information
Specify this parameter when you want to obtain specific replication
information. If you specify this parameter, you must also specify the
model
and serialnum parameters.
If you specify the model and
serialnum
parameters and omit the objectid parameter, information
about all the replications performed by the specified storage subsystem is
obtained.
Specify the objectID obtained from another CLI response. The
value is encoded by the CLI.
replicationsubin
fo
Optional
Specific replication information to be returned
LogicalUnit
is the only value that you can specify.