Table 4-45
GetStorageArray (subtarget=Pool) command parameters
Parameter Name Status
Description
model
Optional
Model of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
serialnum
Optional
Serial number of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.
subtarget
Required
Specify Pool.
poolfunction
Optional
Specify the type of function used to operate the journal pools.
You can specify the following values:
For XP12000/XP10000/SVS200:
•
4
: XP Continuous Access Journal Software
For XP24000/XP20000:
•
3
: XP Snapshot
•
4
: XP Continuous Access Journal Software
•
5
: XP Thin Provisioning Software
If the model or serialnum parameter is omitted, the specification for
this parameter becomes invalid.
You must specify the poolid and poolfunction parameters together.
If the poolid parameter is omitted, the specification for this parameter
becomes invalid.
poolid
Optional
Pool ID of the journal pool
If the model or serialnum parameter is omitted, the specification for
this parameter becomes invalid.
You must specify the poolid and poolfunction parameters together.
If the poolfunction parameter is omitted, the specification for this
parameter becomes invalid.
poolsubinfo
Optional
Information about the journal pool
The values you can specify are LogicalUnit, PairedPool, and
ReplicationInfo
.
Use a comma to delimit multiple values.
clprfilter
Optional
(for
XP24000/
XP20000
and
XP12000/
XP10000/
SVS200)
CLPR number
When XP Continuous Access Journal Software is specified as the type of
function used to operate the journal pools, specify the CLPR number of
the journal volumes.
When XP Thin Provisioning Software is specified as the type of function
used to operate the journal pools, specify the CLPR number of the journal
pool.
This parameter obtains information about the journal pool that consists of
the journal volumes or pool volumes included in the specified CLPR.
You cannot specify the clprfilter parameter if the model,
serialnum
, poolfunction, poolid, and poolsubinfo parameters
are all specified.
poolfilter
Optional
Filter for selecting the type of function used to operate the journal pools.
You can specify the following values:
•
4
: XP Continuous Access Journal Software
•
5
: XP Thin Provisioning Software
Use a comma to delimit multiple values.
You cannot specify the clprfilter parameter if the model,
serialnum
, poolfunction, poolid, and poolsubinfo parameters
are all specified.