HP XP Command View Advanced Edition Software User Manual
Page 279
Command line interface commands
279
Table 4-143
Actions to take for storage subsystem error codes
Storage subsystem
error code
Action
1005,1003
1005,1004
1005,1005
1005,1007
1005,1018
1005,1020
1005,1021
1005,1025
1005,1068
1005,1134
1005,1135
1005,1350
1005,1363
1005,1368
1005,1600
1005,1600
1005,1904
1005,6012
1005,6036
1005,6036
1005,65660
2005,1002
2005,1009
2005,1010
2005,1012
2005,1013
2005,1015
2005,1021
2005,1028
2005,1050
2005,1126
2005,1137
2005,1182
2005,1185
2005,1187
2005,1196
2005,1362
2005,1365
2005,1600
2005,1601
2005,1904
2005,1905
2005,1921
2005,2015
2005,6012
2005,6036
2005,65660
2005,65672
The configuration information of the Device Manager server and the configuration of
the storage subsystem might not match. Perform the following procedure:
1
Execute the AddStorageArray command or RefreshStorageArrays
command.
2
Execute the GetStorageArray command to check whether there is an error in
the batch file.
3
Correct any error in the batch file.
4
Execute the batch functionality again.
If you cannot still resolve this problem, collect the following information, and then
contact your HP technical support representative:
•
Device Manager CLI log file
•
Device Manager CLI property file
•
Contents that you entered on the command line
•
Batch file
•
Device Manager server log files