beautypg.com

Table 4-70 addwwngroup command parameters – HP XP Command View Advanced Edition Software User Manual

Page 180

background image




Command line interface commands



180

is 127. Only WWNs not used for a port can be added. WWNs already existing in a port cannot be
added.

A maximum of 127 WWN groups can be set to a port. For the WWNs to be grouped into a WWN
group, you can specify only the WWNs already set for a port or WWNs newly created. The WWNs
that you specify are added to the port. You cannot add a WWN that belongs to a different WWN
group, or to a different LUN or LUN group.

A user who has only View permission cannot execute this command. A user to whom a user-defined
resource group is assigned, and who also has Modify permission, can execute this command for
any resources.

NOTE:

AddWWNGroup is supported by XP512/XP48 storage subsystems only.

Table 4-70

AddWWNGroup command parameters

Parameter Name Status

Description

serialnum

Required

Serial number of the target storage array to which the WWN group is
added

model

Required

Model of the target storage array to which the WWN group is added

port

Optional

Port number of the WWN group

NOTE:

Specify either port or portname. Do not specify both

parameters at the same time. This might cause an error to occur.

portname

Optional

Port name of the WWN group

NOTE:

Specify either port or portname. Do not specify both

parameters at the same time. This might cause an error to occur.

wwn

Required

Comma-separated list of WWNs to be added to the WWN group

nickname

Required

A unique nickname of the WWN group
You can use the following characters:

A-Z a-z 0-9 ! # $ % & ' ( )
+ - . = @ [ ] ^ _ ` { } ~


The number of characters that can be used for a WWN nickname is 1-8
bytes.

name

Optional

The name given to the WWN group
The number of characters that can be used for a name is 1-64 bytes.

NOTE:

Spaces at the beginning or end of a name are not registered.

Command execution example:

hdvmcli AddWWNGroup -o "D:\logs\XP512 AddWWNGroup.log" serialnum=10001
model=XP512 port=19 wwn=11.55.77.99.33.00.22.66,AA.AA.AA.AA.AA.AA.AA.AA
nickname=hp name=hp

Command execution result:

RESPONSE:

An instance of StorageArray

.

. (Attributes of StorageArray are omitted here)

.

List of 1 Port elements:

An instance of Port

.

. (Attributes of Port are omitted here)