9-5 modifyreplication, Table 4-101 modifyreplication command parameters – HP XP Command View Advanced Edition Software User Manual
Page 224

Command line interface commands
224
Command execution result 2:
RESPONSE
An instance of ReplicationControllerPair
objectID=*****
masterArrayType=XP128
masterSerialNumber=35001
masterControllerID=10
masterStartDevNum=0
masterEndDevNum=255
remoteArrayType=XP1024
remoteSerialNumber=15001
remoteSSID=65534
remoteControllerID=15
remoteStartDevNum=0
remoteEndDevNum=255
*****
: The value is encoded by the CLI.
4-9-5 ModifyReplication
ModifyReplication
changes a copy pair status to split, resync, or restore:
•
Split
: Copying between copy pair has stopped.
•
Resync
: Synchronization is achieved from P-VOL to S-VOL so that their contents match.
•
Restore
: Synchronization is achieved from S-VOL to P-VOL so that their contents match.
(See parameters in
A user who has only View permission cannot execute this command. A user to whom user-defined
resource groups are assigned and who also has Modify permission can specify the allowed
resources. If resources that are not allowed are specified, an error occurs.
Table 4-101
ModifyReplication command parameters
Parameter Name
Status
Description
replicationgroup
id
Required
Specify the copy group number.
operation
Required
Specify one of the following values:
•
split
: Split the copy pair.
•
resync
: Re-synchronize the copy pair from the primary volume (P-
VOL) to the secondary volume (S-VOL).
•
restore
: Re-synchronize the copy pair from S-VOL to P-VOL.
pvolserialnum
Optional
Specify the serial number of the storage subsystem that contains the P-
VOL.
pvoldevnum
Optional
Specify the device number of P-VOL.
This parameter can be specified in decimal, and in colon-separated
hexadecimal. If you specify a hexadecimal number, for
XP12000/XP10000/SVS200, XP1024/XP128, and XP512/XP48, use the
xx:yy format, where xx is the CU number, and yy is the LDEV number.
For XP24000/XP20000, use the ww:xx:yy format, where ww is the
LDKC number, xx is the CU number, and yy is the LDEV number. ww is
optional. If you omit ww, the LDKC number is regarded as 0.
NOTE:
The execution results are output in decimal.