4-4-19 ModifyLogicalUnit
ModifyLogicalUnit
modifies the LU and its corresponding LDEV in a storage device (see
A user to whom a user-defined resource group is assigned, and who has only View permission
cannot execute this command.
Format for XP1024/XP128, XP12000/XP10000/SVS200, and XP24000/XP20000:
hdvmcli [URL] ModifyLogicalUnit [option] serialnum=serial-number model=model
devnum=device-number
{commanddevice={true|false}|commanddevicesecurity={true|false}}
Format for XP512/XP48:
hdvmcli [URL] ModifyLogicalUnit [option] serialnum=serial-number model=model
devnum=device-number commanddevice={true|false}
[commanddevicesecurity={true|false}]
NOTE:
For XP512/XP48, be sure that one or more paths have been set to the logical unit to which
the command executes. If specifying the commanddevicesecurity parameter, use it with the
commanddevice parameter.
NOTE:
For XP1024/XP128, XP12000/XP10000/SVS200, and XP24000/XP20000, specify either
the commanddevice or commanddevicesecurity parameter.
NOTE:
For XP512/XP48, XP1024/XP128, XP12000/XP10000/SVS200, and XP24000/XP20000, if
you change an LU for which security is enabled to a command device, specify both the
commanddevice
and commanddevicesecurity parameters.
Table 4-50
ModifyLogicalUnit command parameters
Parameter Name
Status
Description
serialnum
Required
Serial number of the storage array of the LU
model
Required
Model of the storage array of the LU
devnum
Required
Device number of the LU
This parameter can be specified in decimal, and in colon-separated
hexadecimal. If you specify a hexadecimal number, for
XP12000/XP10000/SVS200, XP1024/XP128, and XP512/XP48, use the
xx:yy format, where xx is the CU number, and yy is the LDEV number.
For XP24000/XP20000, use the ww:xx:yy format, where ww is the
LDKC number, xx is the CU number, and yy is the LDEV number. ww is
optional. If you omit ww, the LDKC number is regarded as 0.
NOTE:
The execution results are output in decimal.
commanddevice
Optional
New setting for command device
Specify true to set the specified LU as a command device, and false
to release the setting.
commanddevicesec
urity
Optional
Security mode setting for the command device
Specify true to enable security, and false to disable it.
If you are using XP512/XP48 and you specify this parameter, you must
also specify the commanddevice parameter.
Command execution example:
hdvmcli ModifyLogicalUnit -o "D:\logs\XP1024 ModifyLogicalUnit.log"
"serialnum=10001" "model=XP1024" "devnum=1" "commanddevice=true"